On Line ORP Meters

PO 650 On Line ORP Meter

MOQ : 10 Units

  • Accuracy
  • 1% of Full Scale
  • Application Media
  • Industrial water, waste water & process applications
  • Color
  • Grey
  • Dimension (L*W*H)
  • 96 x 96 x 110 mm
  • Display Type
  • Other, 4-Digit LED Display
  • Material
  • ABS Plastic Housing
  • Measurement Range
  • -1999 to +1999 mV
  • Measuring Units
  • mV (millivolts)
  • Model
  • PO 650
  • Mounting
  • Wall Mounting
  • Operating Temperature
  • 0C to 50C
  • Output
  • 4-20 mA, Isolated
  • Power Consumption
  • Approx. 4 VA
  • Power Supply
  • 230V AC 10%, 50Hz
  • Process Connection
  • Threaded / Submersible
  • Protection
  • IP65
  • Range
  • -1999 to +1999 mV
  • Response Time
  • < 5 sec
  • Sensor Type
  • Electrochemical (ORP Electrode)
  • Stability
  • Drift < 2 mV/24 hr

UT-650 ORP Meter

MOQ : 10 Units

  • Equipment Type
  • Digital ORP Meter
  • Accuracy
  • 2 mV
  • Application Media
  • Liquid (Water, Solution, etc.)
  • Color
  • Blue and Grey
  • Connecting Type
  • BNC Connector
  • Connector
  • BNC Socket
  • Diameter
  • 35 mm
  • Dimension (L*W*H)
  • 185 x 40 x 35 mm
  • Display Type
  • Other, 4-digit LCD Display
  • Housing Material
  • ABS
  • Material
  • ABS Plastic
  • Measurement Range
  • -1999 mV to 1999 mV
  • Measuring Units
  • mV
  • Model
  • UT-650
  • Mounting
  • Handheld
  • Operating Temperature
  • 0C to 50C
  • Power Consumption
  • 2 mA
  • Power Supply
  • DC 9V Battery
  • Process Connection
  • Direct Immersion
  • Protection
  • IP55 Rated
  • Range
  • -1999 mV to 1999 mV
  • Resolution
  • 1 mV
  • Response Time
  • 10 seconds
  • Sensor Type
  • Platinum Electrode
  • Signal Type
  • ORP (Oxidation Reduction Potential)
  • Stability
  • 1 mV/3h
  • Storage Temperature
  • -20C to 60C
  • Temperature Range
  • 0C to 50C

Spare ORP Sensor

MOQ : 10 Units

  • Accuracy
  • 2 mV
  • Application Media
  • Water, Wastewater, Process Applications
  • Color
  • Clear & Black
  • Connecting Type
  • Cable
  • Connectivity Type
  • Wired Cable
  • Connector
  • BNC or Cable End
  • Diameter
  • 12 mm
  • Dimension (L*W*H)
  • 120 mm (L) x 12 mm (Dia)
  • Housing Material
  • Epoxy
  • Humidity %
  • < 85%
  • Length
  • 120 mm
  • Material
  • Glass & Epoxy Body
  • Measurement Range
  • -1000 to +1000 mV
  • Measuring Units
  • mV
  • Model
  • Spare ORP Sensor
  • Mounting
  • Immersion, Submersion, In-line
  • Operating Temperature
  • 0C to 80C
  • Output
  • Millivolt Signal
  • Pressure Range
  • 0-6 bar
  • Process Connection
  • PG13.5 Thread
  • Protection
  • IP68
  • Range
  • -1000 to +1000 mV
  • Resolution
  • 1 mV
  • Response Time
  • < 30 sec
  • Sensitivity
  • High
  • Sensor Type
  • ORP (Oxidation Reduction Potential)
  • Signal Type
  • Analog
  • Stability
  • Drift < 2 mV/month
  • Storage Temperature
  • -10C to 50C
  • Temperature Range
  • 0C to 80C


Back to top